1. Home
  2. Part L Compliance
  3. SAP vs SBEM vs DSM: Which Calculation Does Your Building Need?

SAP vs SBEM vs DSM: Which Calculation Does Your Building Need?

Working to Part L 2021 (Approved Document L, volumes 1 and 2)

SAP, SBEM and dynamic simulation modelling (DSM) are the three calculation methods used to show Part L compliance in England. Which one applies depends first on whether the building is a dwelling or not, and then, for non-domestic buildings, on how complex it is. All three compare the proposed design against a notional building with the same geometry, and all three are needed twice: at design stage and as built.

Talk to an engineer or call 0114 312 1105

Which Method Does Your Project Need?

How the Methods Differ

SAP (the Standard Assessment Procedure) covers dwellings only. It calculates energy use for heating, hot water, lighting and ventilation for the home as a whole, and checks the dwelling emission rate, primary energy rate and fabric energy efficiency against their targets. We run SAP in Elmhurst as an OCDEA.

SBEM (the Simplified Building Energy Model) covers non-domestic buildings. It works zone by zone with standard activity profiles, on a monthly basis, and checks the building emission rate and primary energy rate against the targets along with the limiting fabric and services standards.

DSM covers the same non-domestic buildings as SBEM, using approved software such as IES VE. It calculates hour by hour, so it represents thermal mass, natural and mixed-mode ventilation, glazing and complex controls more closely. The result is still a BRUKL report, checked against the same criteria.

SBEM or DSM?

For a non-domestic building, either route is accepted. SBEM is quicker and suits straightforward buildings. DSM is the better choice where the building relies on features a monthly method represents poorly, or where a dynamic model is needed anyway for overheating (TM52, BB101), operational energy (TM54) or BREEAM. If the dynamic model exists, using it for Part L avoids building a second model.

Mixed-Use Schemes

A building with flats above commercial units needs both methods: SAP for each dwelling and SBEM or DSM for the non-domestic parts, with the communal and commercial areas assessed on the non-domestic side. Planning energy statements usually need the results combined across the whole site, so it helps to have both calculations from one consultant. Contact us with the drawings and we will confirm how the scheme splits before any modelling starts.

Last reviewed: November 2026

Questions

FAQs

Can SBEM be used for a block of flats?

No. Each dwelling is assessed with SAP. SBEM or DSM applies only to non-domestic spaces in the building, such as commercial units on the ground floor.

Does DSM give a better Part L result than SBEM?

Not by default. The two methods can give different results for the same building because DSM models it in more detail, which can help or hinder. The reason to choose DSM is that it represents the building more accurately, not that it passes more easily.

Are student accommodation and care homes assessed with SAP or SBEM?

It depends on how the building is arranged and used. Cluster flats and care homes are often assessed as non-domestic buildings, while self-contained studios can be treated as dwellings. We confirm the route with building control early.

Talk to an Engineer

Send us the drawings and we will confirm which calculation applies before any modelling starts.

Talk to an engineer

Accredited by

CIBSE Low Carbon Energy AssessorCIBSE Low Carbon ConsultantElmhurst Energy Approved

Get in touch

Send drawings, fee proposal within 1 working day.

Office address
Spaces Acero, 1 Concourse Way, Sheffield, S1 2BJ
How we use your details