BREEAM's energy credits are earned in two places. Ene 01, Reduction of Energy Use and Carbon Emissions, scores the building's regulated energy performance against the Part L baseline. Ene 02, Prediction of Operational Energy Consumption, scores how well the team has predicted and planned for the energy the building will actually use. Walker Energy Analysis provides the modelling and the assessor-ready evidence for both, in IES Virtual Environment.

Talk to an engineer or call 0114 312 1105

Ene 01: Regulated Energy Performance

Ene 01 is assessed from the same Part L2 compliance model that produces your BRUKL report. The credits are awarded on a performance scale that compares the building's predicted regulated energy, primary energy and CO2 emissions with the notional building, so every improvement in fabric, services and lighting that helps building control also moves the BREEAM score. If you already need a Part L2 assessment, the same model supports this credit directly: see our Part L2 BRUKL and EPC service.

What we provide for Ene 01:

  • Part L2 model built to the National Calculation Methodology in IES VE, at design stage and as built
  • The BRUKL output and energy performance figures in the format the BREEAM calculator and your assessor need
  • Option testing where the score sits close to a credit threshold: fabric, glazing, lighting, heat recovery, renewables

Ene 02: Operational Energy Prediction

Ene 02 looks past compliance at the energy the building is likely to use in operation, including unregulated loads such as small power, lifts, catering and servers. Under Version 7 the credit uses benchmarked energy use intensity and carbon intensity metrics, and rewards a credible prediction made early enough to influence the design. The method is the one set out in CIBSE TM54 (2022): a scenario-based model of the building in use, with occupancy, hours and equipment agreed with the design team, and the assumptions recorded so they can be checked against the meters later. See our TM54 operational energy service.

What we provide for Ene 02:

  • TM54 operational energy model in IES VE, with low, central and high scenarios
  • Energy use intensity and carbon intensity reporting against the BREEAM benchmarks
  • A record of the assumptions and the targets set, ready for the assessor and any independent review

Under the 2018 Scheme

On projects registered under BREEAM UK New Construction 2018 (Version 6), the operational energy prediction sat inside Ene 01 as its second part, worth up to four credits. The modelling is the same; only the credit it reports to changes. Tell us which version your project is registered under and we structure the report to match.

Why BREEAM Assessors Work With Us

We're a specialist energy consultancy. This is the core of what we do, not a sideline. The Part L2 and TM54 models are built in IES VE as standard, we turn changes around quickly, and the outputs come back in the format your assessor can use immediately.

Last reviewed: November 2026

Questions

FAQs

Can the Part L2 model be reused for Ene 01?

Yes. Ene 01 is assessed from the BRUKL output of the Part L2 compliance model, so one model serves building control and BREEAM.

Is TM54 modelling the same as the Part L calculation?

No. Part L and Ene 01 cover regulated energy against a notional building. TM54 and Ene 02 predict total energy in use, including unregulated loads, with realistic hours and occupancy.

How many credits are available?

It depends on the scheme version the project is registered under and on the building type; your BREEAM assessor confirms the number for the project. We model to the thresholds that matter and tell you how close each one is.

When should the Ene 02 prediction be done?

Early. The credit rewards a prediction made while the design can still change, and the same model is reused for GLA be seen reporting and for checking the building once it is in use.

Talk to an Engineer

Tell us which BREEAM version your project is registered under and which energy credits you are targeting.

Talk to an engineer

Accredited by

CIBSE Low Carbon Energy AssessorCIBSE Low Carbon ConsultantElmhurst Energy Approved

Get in touch

Send drawings, fee proposal within 1 working day.

Office address
Spaces Acero, 1 Concourse Way, Sheffield, S1 2BJ
How we use your details